Filton College has been working with local and regional employers in the fuel engineering sector for many years, providing courses for the Accredited Certification Scheme (ACS). These are designed and monitored by such prestigious groups as City and Guilds, Corgi and British Gas. Certification is accredited by the Construction Industry Training Board (CITB).
The ACS Level 2 and 3
The ACS Level 2 & 3 courses provide for people who are already working within the gas industry but who need to be upskilled or re-trained to obtain the accredited qualifications recognised by the sector.
Domestic Natural Gas |
Install |
Exchange |
Disconnect |
Remove |
Service |
Repair |
Breakdown |
Commission |
Code |
Gas Type |
|---|---|---|---|---|---|---|---|---|---|---|
Core Domestic Nat Gas Safety |
|
|
|
|
|
|
|
|
CCN1 |
NG |
Cooking Appliances |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
CKR1 |
NG |
Fires and Wall Heaters |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
HTR1 |
NG |
Water Heating Appliances |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
WAT1 |
NG |
Central Heating Boilers <60kW |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
CEN1 |
NG |
Meters |
Yes |
Yes |
|
Yes |
|
|
|
Yes |
MET1 |
NG |
Domestic Liquefied Petroleum Gas |
Install |
Exchange |
Disconnect |
Remove |
Service |
Repair |
Breakdown |
Commission |
Code |
Gas Type |
|---|---|---|---|---|---|---|---|---|---|---|
Core Domestic LPG Gas Safety |
|
|
|
|
|
|
|
|
CCLP1 |
LPG |
Commercial Catering |
Install |
Exchange |
Disconnect |
Remove |
Service |
Repair |
Breakdown |
Commission |
Code |
Gas Type |
|---|---|---|---|---|---|---|---|---|---|---|
Core Commercial Catering Safety |
|
|
|
|
|
|
|
|
CCN1 |
NG |
Catering Appliances - Table 1 |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
COM |
NG |
Catering Appliances - Table 2 |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
COM |
NG |
Catering Appliances - Table 3 |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
COM |
NG |
Commercial |
Install |
Exchange |
Disconnect |
Remove |
Service |
Repair |
Breakdown |
Commission |
Code |
Gas Type |
|---|---|---|---|---|---|---|---|---|---|---|
Core Commercial N Gas Safety |
|
|
|
|
|
|
|
|
COCN1 |
NG |
Core Commercial LP Gas Safety |
|
|
|
|
|
|
|
|
COCLP1 |
LPG |
First Fix Pipe Installation <75 mbar |
Yes |
Yes |
Yes |
|
|
|
|
|
ICPN1 |
NG/LPG |
First Fix Commercial Appliances |
Yes |
|
|
|
|
|
|
|
ICAE1 |
NG/LPG |
Test & Purge - UP/1 (<7 bar NG) or (<2 bar LPG) |
|
|
|
|
|
|
Yes |
TPCP1 |
NG/LPG |
|
Test & Purge UP/1A (low press.) |
|
|
|
|
|
|
|
Yes |
TPCP1A |
NG |
Indirect Fired Heating Appliances |
Yes |
|
|
|
Yes |
Yes |
Yes |
Yes |
CIGA1 |
NG/LPG |
Overhead Radiant Heaters |
Yes |
|
|
|
Yes |
Yes |
Yes |
Yes |
CORT1 |
NG/LPG |